Tag Archives: residential

Western Mass Knob and Tube

In Western Massachusetts  Knob and Tube wiring was a standardwestern mass knob and tube 150x89 Western Mass Knob and Tube system of open electrical conductors supported on ceramic knobs. It also used ceramic knobs where wires cross each other or pass through framing. This type of wiring was in common use from the 1880′s to 1930′s, in North America.

In Western Mass during this era when knob and tube was in common use, a typical home would have 30 or 60 amp electrical service, sufficient for general lighting and maybe a radio. In those days people were still using  “iceboxes”, wood or gas stoves, coal heat, and no air conditioning. Professional wiring by electricians in  homes was a new trade and there were very few rules.

American Electricians Handbook was the first home wiring guide to electrical rules which appeared around the turn of the century, when Terrell Croft wrote the  Crofts books defining early wiring practices. One of Croft’s rules was that knob and tube wiring should always be run through, never over the house framing. The problem with running wiring over framing is that it can get bumped, snagged, and damaged.

The advantage of knob and tube wiring is that it dissipates heat into free air, and therefore has a higher ampacity than cable systems with equivalent wire size. When originally installed in the 1900′s knob and tube wiring was less expensive than other wiring methods. Due to the installation cost, owners and electricians would opt for knob and tube versus conduit wiring and metal junction boxes. The conduit methods were known to be of better quality, but their cost was significantly higher than knob and tube wiring.

Modern wiring methods assume two or more load carrying conductors will lie against each other, for instance the standard non-metallic – 2 cable. Since the load carrying wires are in close proximity, when they heat up, the heating is shared across the wires, limiting the overall current load they can support. Since the load carrying wires in knob and tube wiring are widely spaced, the wires are capable of carrying higher loads without risk of fire.

Knob and tube wiring was usually insulated with cotton cloth and soft rubberand porcelain insulators. Although the actual wire covering may have degraded over the decades, the porcelain insulators have a very long lifespan and will keep any bare wires safely insulated. These same porcelain insulators were used with bare wire electric fencing for livestock. These insulators can carry very high voltage surges without the risk of shorting to ground. Many electricians understand that by running the hot and neutral conductors farther apart from each other than today’s electrical cabling does make shorts between those conductors less likely, at the same time realizing there is not a grounding conductor.

Knob and tube is insufficient for current usage patterns. Contemporary households use a wide range and intensity of electrical equipment that was unforeseen at the time of knob and tube inception. Household power use increased following World War II, first generation wiring systems became susceptible to abuse by homeowners, who would avoid repeated blown fuses by over fusing the circuits, thus subjecting the wiring to heat damage due to higher levels of current.desellier logo1 Western Mass Knob and Tube

In many instances deterioration and abuse have rendered the wiring unsafe. During building renovations and remodeling wiring can become damaged. The rubber insulation will become dried out, brittle when handled, damage by rodent, or simple carelessness…

If you live in Western Massachusetts and you’re concerned about the Knob and Tube wiring in your home, give us a call for an in home inspection and estimate.

Ron Desellier Electric   (413) 478-6192

_________________________________________

Technorati Tags: , , , , , , , , , , , , , , , , , , , , , , , , ,

Read full storyComments { 0 }

Western Mass Septic Services

TEC Environmental

Local Company Serving all of Western Massachusetts

blackberry 151 300x225 Western Mass Septic Services

TEC  ENVIRONMENTAL (413) 949-1060

Specializing In:

  • Residential and Commercial Septic Tank Pumping

  • Grease Trap Pumping

  • Commercial Jetting Service

  • Title V Inspections

  • Municipal Liquid Waste Transportation Services

  • Septic System Design and Installation

  • Consultation Services

Member of the Greater Springfield Chamber of Commerce

TEC ENVIRONMENTAL has gone Green! Contact us for a personal 1 on 1 consultation on how we can work together on lowering your impact on the environment and reducing your Carbon Footprint.

The DEP recommends you have your Septic Tank pumped every two years.

We offer service Maintenance contracts to all our valued customers.

Leave it up to us and avoid costly repairs and unnecessary failures.

let us handle your needs today…

Contact Glenn Riddle

Phone (413) 949-1060

Email TecEnvConsult@gmail.com



Technorati Tags: , , , , , ,

Read full storyComments { 0 }

Videos, Slideshows and Podcasts by Cincopa Wordpress Plugin